The X300 transmitter family are CDI’s mid-sized TRAXALL compatible electromagnetic transmitters. This family consists of four transmitters which house 2, 3, 4 or 5 C-Cell batteries. These transmitters have both user-adjustable frequency and output power through the use of CDI’s FieldLink wireless communications system. Using CDI’s TRAXALL transmitters, an operator may have direct control over battery life vs. strength tradeoffs. Short pig runs can go for maximum power and long pig runs can be more conservative with pulsing modes and/or reduced power.

CDI X300-C Family

CDI C-Cell Transmitters (Mid-Size) X300-2C

X300-2C Specifications

Line Sizes 6″ – 24″ [152mm – 610mm]
Pressure 2,500psi [172 bar]
Length 5.77″ [146.5mm]
Diameter 1.74″ [44.2mm]
Material 304L Stainless Steel (Titanium high pressure available)
Temp Range -40°C to 60°C using standard alkaline batteries
Higher temperatures are available with specialized batteries.
End Caps Knurled, hand-tightened

Battery Life vs Range

Alkaline Batteries Lithium Batteries
Maximum Range Range:

Constant:

Pulsing:

50.0 ft (15.2m)

299 hrs

1,230 hrs

67 ft (20.4m)

248 hrs

744 hrs

Optimal Power * Range:

Constant:

Pulsing:

32.5 ft (9.9m)

466 hrs

1,400 hrs

41.4 ft (12.6m)

315 hrs

947 hrs

Maximum Life * Range:

Constant:

Pulsing:

20.1 ft (6.1m)

1,134 hrs

28,748 hrs

21 ft (6.4m)

1,014 hrs

25,694 hrs

* Unless otherwise requested transmitters ship in Max Range mode and constant transmission. Optimal Power and Max Life modes require programming with FieldLink USB and Configurator software.
CDI C-Cell Transmitters (Mid-Size) X300-3C

X300-3C Specifications

Line Sizes 8″ – 28″ [203mm – 711mm]
Pressure 2,500psi [172 bar]
Length 7.74″ [196.6mm]
Diameter 1.74″ [44.2mm]
Material 304L Stainless Steel (Titanium high pressure available)
Temp Range -40°C to 60°C using standard alkaline batteries
Higher temperatures are available with specialized batteries.
End Caps Knurled, hand-tightened

Battery Life vs Range

Alkaline Batteries Lithium Batteries
Maximum Range Range:

Constant:

Pulsing:

62.8 ft (19.1m)

102 hrs

306 hrs

75 ft (22.9m)

48 hrs

146 hrs

Optimal Power * Range:

Constant:

Pulsing:

51.6 ft (15.7m)

196 hrs

588 hrs

60.8 ft (18.5m)

128 hrs

385 hrs

Maximum Life * Range:

Constant:

Pulsing:

30.0 ft (9.1m)

969 hrs

24,568 hrs

38 ft (11.6m)

732 hrs

18,564 hrs

* Unless otherwise requested transmitters ship in Max Range mode and constant transmission. Optimal Power and Max Life modes require programming with FieldLink USB and Configurator software.
CDI C-Cell Transmitters (Mid-Size) X300-4C

X300-4C Specifications

Line Sizes 12″ and larger [305mm and up]
Pressure 2,500psi [172 bar]
Length 9.61″ [244mm]
Diameter 1.74″ [44.2mm]
Material 304L Stainless Steel (Titanium high pressure available)
Temp Range -40°C to 60°C using standard alkaline batteries
Higher temperatures are available with specialized batteries.
End Caps Knurled, hand-tightened

Battery Life vs Range

Alkaline Batteries Lithium Batteries
Maximum Range Range:

Constant:

Pulsing:

67 ft (20.4m)

232 hrs

696 hrs

76 ft (23.2m)

118 hrs

352 hrs

Optimal Power * Range:

Constant:

Pulsing:

60.0 ft (18.3m)

266 hrs

798 hrs

72.7 ft (22.2m)

187 hrs

561 hrs

Maximum Life * Range:

Constant:

Pulsing:

50.0 ft (15.2m)

1,055 hrs

34,596 hrs

74.1 ft (22.6m)

847 hrs

21,471 hrs

* Unless otherwise requested transmitters ship in Max Range mode and constant transmission. Optimal Power and Max Life modes require programming with FieldLink USB and Configurator software.
CDI C-Cell Transmitters (Mid-Size) X300-5C

X300-5C Specifications

Line Sizes 14″ and larger [356mm and up]
Pressure 2,500psi [172 bar]
Length 11.54″ [393mm]
Diameter 1.74″ [44.2mm]
Material 304L Stainless Steel (Titanium high pressure available)
Temp Range -40°C to 60°C using standard alkaline batteries
Higher temperatures are available with specialized batteries.
End Caps Knurled, hand-tightened

Battery Life vs Range

Alkaline Batteries Lithium Batteries
Maximum Range Range:

Constant:

Pulsing:

73.7 ft (22.5m)

277 hrs

832 hrs

90.9 ft (27.7m)

132 hrs

398 hrs

Optimal Power * Range:

Constant:

Pulsing:

68.4 ft (20.8m)

312 hrs

937 hrs

80.4 ft (24.5m)

220 hrs

660 hrs

Maximum Life * Range:

Constant:

Pulsing:

36.3 ft (11m)

1,000 hrs

35,098 hrs

51.1 ft (15.6m)

877 hrs

26,293 hrs

* Unless otherwise requested transmitters ship in Max Range mode and constant transmission. Optimal Power and Max Life modes require programming with FieldLink USB and Configurator software.