SureLaunch

WeldFit specializes in the design, engineering, manufacturing and quality testing of automated pigging systems that can be utilized to perform four separate pigging functions: liquid recovery, cleaning, batching and in-line inspections. The SureLaunchTM automated pigging system can launch any type of pig individually at pre-set launch intervals through the use of a logic-driven control system and an electrical drive system. The horizontally oriented automatic launcher design is loaded with multiple pigs in one loading operation that allows the launching of a single cleaning pig, batching pig or spherical pig for both liquid and gas pipeline service applications.

KEY FEATURES & BENEFITS:

  • Horizontal design eliminates access platforms and lifting equipment to reduce safety risks, transportation costs and field installation costs
  • The mechanical launch mechanism ensures pig launches in high and low flow conditions
  • The flow-through barrel design of the automated pigging system removes the need to open and close valves for each pig launch, resulting in an increase of the valve operating service-life and a reduction of  maintenance costs, environmental emissions and safety risk exposure
  • The electric drive system can be powered by 115 VAC or 24 VDC Class 1, Division 1 & 2 compliant power to eliminate supply gas, supply gas treatment and emissions
  • Launch system is controlled by drive system that allows any type of pig to be launched to meet operator?s specific pigging requirements
  • Standard automated pig launcher is designed to accommodate up to seven cleaning pigs or length of typical in-line inspection tools
  • Standard receiver is designed to accommodate up to eight cleaning pigs or length of typical in-line inspection tools
  • Primer coated ready for customer desired paint system or painted to customer?s paint specification
  • Quick opening closure standard on all units
  • Designed with the appropriate quantity and size of nozzles for vents, pressure gauges and drains
  • Data Package provided for code compliance
  • Hydrostatic pressure tested in accordance with the applicable codes
  • All units are skid mounted
  • Ethernet/IP address for remote access capabilities
  • Designed to applicable safety design factor
  • Inspected and designed in accordance to the applicable pipeline codes (B31.8, B31.4, B31.3, Sec. VIII Div. 1)

OPTIONS:

  • Semi-automated capabilities without logic-driven controls
  • Semi-automated systems can be equipped with electric drive motor or can be manually operated when electric power is not available
  • Corrosion coupon holders for monitoring internal corrosion rates
  • Pull nozzles for loading in-line inspection tools
  • Overlays of trap components for corrosive service applications
  • Valve packages available upon request
  • In-Field application engineering, project management, training and commissioning services
  • Extruded nozzles eliminate tees and reduce girth welds on the outlets during field installation

SPECIFICATIONS:

  • Sizes: 4″ nominal to 42″ nominal line pipe
  • Barrel Capacity:
    • Launcher – 7 Cleaning pigs (2D) or length of one ILI tool
    • Receiver – 8 Cleaning pigs (2D) or length of one ILI tool
  • Pressure Rating: ANSI 150#, 300#, 600#, 900# & 1500#
  • Product: Liquid and Gas Service
  • Product Temperature Range: -50° F to 150° F
  • Power Options: 24VDC, 115VAC or 230 VAC
  • HMI: EXOR eTOP507G 7″ TFT widescreen
    • CPU – ARM CORTEX-A8 ? 600 MHz
    • User Memory – 128 MB Flash
    • Serial – RS-232, RS-485, RS-422
    • Ethernet – Two 1-/100 Mbit with integrated switch
    • USB – Two Host Interfaces
    • Temperature Range: -25° F to 140° F
  • Explosion Proof Rating: Class 1, Div. 2 Haz Loc
  • Environmental Rating: NEMA 4X / IP66

PDF